mirror of
https://github.com/openstreetmap/id-tagging-schema.git
synced 2025-10-26 04:13:50 +01:00
Update power presets following transformer tagging extension (#447)
This commit is contained in:
parent
57c0a7e5d2
commit
de6fce4c7f
7 changed files with 71 additions and 18 deletions
|
|
@ -1655,6 +1655,18 @@
|
|||
"old": {"townhall:village": "yes"},
|
||||
"replace": {"amenity": "townhall", "townhall:type": "village"}
|
||||
},
|
||||
{
|
||||
"old": {"transformer": "auto"},
|
||||
"replace": {"transformer": "yes", "windings:auto": "yes"}
|
||||
},
|
||||
{
|
||||
"old": {"transformer": "minor_distribution"},
|
||||
"replace": {"transformer": "distribution"}
|
||||
},
|
||||
{
|
||||
"old": {"transformer": "traction"},
|
||||
"replace": {"transformer": "main"}
|
||||
},
|
||||
{
|
||||
"old": {"tunnel": "1"},
|
||||
"replace": {"tunnel": "yes"}
|
||||
|
|
@ -1747,6 +1759,22 @@
|
|||
"old": {"volcano": "extinct"},
|
||||
"replace": {"volcano:status": "extinct"}
|
||||
},
|
||||
{
|
||||
"old": {"voltage-high": "*", "transformer":"generator"},
|
||||
"replace": {"voltage:secondary":"$1", "transformer":"generator"}
|
||||
},
|
||||
{
|
||||
"old": {"voltage-low": "*", "transformer":"generator"},
|
||||
"replace": {"voltage:primary":"$1", "transformer":"generator"}
|
||||
},
|
||||
{
|
||||
"old": {"voltage-high": "*"},
|
||||
"replace": {"voltage:primary":"$1"}
|
||||
},
|
||||
{
|
||||
"old": {"voltage-low": "*"},
|
||||
"replace": {"voltage:secondary":"$1"}
|
||||
},
|
||||
{
|
||||
"old": {"wall_type": "noise_barrier"},
|
||||
"replace": {"wall": "noise_barrier"}
|
||||
|
|
|
|||
|
|
@ -4,14 +4,13 @@
|
|||
"label": "Type",
|
||||
"strings": {
|
||||
"options": {
|
||||
"distribution": "Distribution",
|
||||
"generator": "Generator",
|
||||
"converter": "Converter",
|
||||
"traction": "Traction",
|
||||
"auto": "Autotransformer",
|
||||
"phase_angle_regulator": "Phase Angle Regulator",
|
||||
"auxiliary": "Auxiliary",
|
||||
"yes": "Unknown"
|
||||
"main": "Forwards power",
|
||||
"distribution": "Feeds final consumers, installed outside substations",
|
||||
"generator": "Steps-up voltage in power plants",
|
||||
"converter": "Feeds power converters",
|
||||
"phase_angle_regulator": "Regulates phase angle",
|
||||
"auxiliary": "Feeds internal systems in substations",
|
||||
"yes": "Unknown role"
|
||||
}
|
||||
},
|
||||
"autoSuggestions": false,
|
||||
|
|
|
|||
12
data/fields/windings/auto.json
Normal file
12
data/fields/windings/auto.json
Normal file
|
|
@ -0,0 +1,12 @@
|
|||
{
|
||||
"key": "windings:auto",
|
||||
"type": "check",
|
||||
"label": "Autotransformer",
|
||||
"strings": {
|
||||
"options": {
|
||||
"undefined": "Assumed to be No",
|
||||
"yes": "Yes",
|
||||
"no": "No"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
|
@ -5,6 +5,10 @@
|
|||
"power/line",
|
||||
"power/minor_line",
|
||||
"man_made/pipeline",
|
||||
"power/cable/underground"
|
||||
"power/cable",
|
||||
"power/generator",
|
||||
"power/plant",
|
||||
"power/switch",
|
||||
"power/transformer"
|
||||
]
|
||||
}
|
||||
|
|
|
|||
|
|
@ -10,10 +10,8 @@
|
|||
"power": "*"
|
||||
},
|
||||
"fields": [
|
||||
"power"
|
||||
],
|
||||
"moreFields": [
|
||||
"material"
|
||||
"power",
|
||||
"operator"
|
||||
],
|
||||
"searchable": false,
|
||||
"name": "Power Feature"
|
||||
|
|
|
|||
|
|
@ -16,7 +16,8 @@
|
|||
"voltage/secondary",
|
||||
"voltage/tertiary",
|
||||
"windings",
|
||||
"windings/configuration"
|
||||
"windings/configuration",
|
||||
"windings/auto"
|
||||
],
|
||||
"geometry": [
|
||||
"point",
|
||||
|
|
|
|||
|
|
@ -3339,20 +3339,20 @@ en:
|
|||
# transformer=*
|
||||
label: Type
|
||||
options:
|
||||
# transformer=auto
|
||||
auto: Autotransformer
|
||||
# transformer=auxiliary
|
||||
auxiliary: Auxiliary
|
||||
# transformer=compensator
|
||||
compensator: Compensation feed
|
||||
# transformer=converter
|
||||
converter: Converter
|
||||
# transformer=distribution
|
||||
distribution: Distribution
|
||||
# transformer=generator
|
||||
generator: Generator
|
||||
# transformer=main
|
||||
main: Main
|
||||
# transformer=phase_angle_regulator
|
||||
phase_angle_regulator: Phase Angle Regulator
|
||||
# transformer=traction
|
||||
traction: Traction
|
||||
# transformer=yes
|
||||
'yes': Unknown
|
||||
trees:
|
||||
|
|
@ -3590,6 +3590,17 @@ en:
|
|||
# windings field placeholder
|
||||
placeholder: 1, 2, 3...
|
||||
terms: '[translate with synonyms or related terms for ''Windings'', separated by commas]'
|
||||
windings/auto:
|
||||
# windings:auto=*
|
||||
label: Auto-transformer
|
||||
options:
|
||||
# windings:auto=no
|
||||
'no': 'No'
|
||||
# windings:auto=undefined
|
||||
undefined: Assumed to be No
|
||||
# windings:auto=yes
|
||||
'yes': 'Yes'
|
||||
terms: '[translate with synonyms or related terms for ''Auto-transformer'', separated by commas]'
|
||||
windings/configuration:
|
||||
# windings:configuration=*
|
||||
label: Windings Configuration
|
||||
|
|
|
|||
Loading…